Молимо вас користите овај идентификатор за цитирање или овај линк до ове ставке: https://scidar.kg.ac.rs/handle/123456789/10204
Назив: Theoretical-experimental determining of cooling time (t<inf>8/5</inf>) in hard facing of steels for forging dies
Аутори: Lazic, Vukic
Sedmak, Aleksandar
Zivkovic, Miroslav
Aleksandrovic, Srbislav
Čukić, Rajko
Jovicic, Radomir
Ivanović, Ivana
Датум издавања: 2010
Сажетак: This paper investigates the accuracy of analytical, empirical, and numerical expressions, i. e. the most favourable methods for calculating the cooling time from 800 to 500 °C (t8/5). The degree of accuracy of time t8/5 is very significant, because it determines the cooling rate, and consequently the structural changes in heat affected zone for hard faced layers. Based on the presented results, one can conclude that the finite element method provides the best conformity with the experiment and among analytical and empirical formulas the same goes for the expression of Japanese authors, for the case of hard facing of plane and prismatic parts.
URI: https://scidar.kg.ac.rs/handle/123456789/10204
Тип: article
DOI: 10.2298/TSCI1001235L
ISSN: 0354-9836
SCOPUS: 2-s2.0-77954432165
Налази се у колекцијама:Faculty of Engineering, Kragujevac