Молимо вас користите овај идентификатор за цитирање или овај линк до ове ставке: https://scidar.kg.ac.rs/handle/123456789/10512
Назив: Patient-specific prediction of coronary plaque growth from CTA angiography: A multiscale model for plaque formation and progression
Аутори: Parodi O.
Exarchos T.
Marraccini P.
Vozzi, Federico
Milosevic Z.
Nikolic, Dalibor
Sakellarios, Antonis
Siogkas, Panagiotis
Fotiadis D.
Filipovic, Nenad
Датум издавања: 2012
Сажетак: Computational fluid dynamics methods based on in vivo 3-D vessel reconstructions have recently been identified the influence of wall shear stress on endothelial cells as well as on vascular smooth muscle cells, resulting in different events such as flow mediated vasodilatation, atherosclerosis, and vascular remodeling. Development of image-based modeling technologies for simulating patient-specific local blood flows is introducing a novel approach to risk prediction for coronary plaque growth and progression. In this study, we developed 3-D model of plaque formation and progression that was tested in a set of patients who underwent coronary computed tomography angiography (CTA) for anginal symptoms. The 3-D blood flow is described by the Navier-Stokes equations, together with the continuity equation. Mass transfer within the blood lumen and through the arterial wall is coupled with the blood flow and is modeled by a convection-diffusion equation. The low density lipoprotein (LDL) transports in lumen of the vessel and through the vessel tissue (which has a mass consumption term) are coupled by Kedem-Katchalsky equations. The inflammatory process is modeled using three additional reaction-diffusion partial differential equations. A full 3-D model was created. It includes blood flow and LDL concentration, as well as plaque formation and progression. Furthermore, features potentially affecting plaque growth, such as patient risk score, circulating biomarkers, localization and composition of the initial plaque, and coronary vasodilating capability were also investigated. The proof of concept of the model effectiveness was assessed by repetition of CTA, six months after. © 2012 IEEE.
URI: https://scidar.kg.ac.rs/handle/123456789/10512
Тип: article
DOI: 10.1109/TITB.2012.2201732
ISSN: 1089-7771
SCOPUS: 2-s2.0-84866604957
Налази се у колекцијама:Faculty of Engineering, Kragujevac
Institute for Information Technologies, Kragujevac

Број прегледа

201

Број преузимања

7

Датотеке у овој ставци:
Датотека Опис ВеличинаФормат 
PaperMissing.pdf
  Ограничен приступ
29.86 kBAdobe PDFСличица
Погледајте


Ставке на SCIDAR-у су заштићене ауторским правима, са свим правима задржаним, осим ако није другачије назначено.