Молимо вас користите овај идентификатор за цитирање или овај линк до ове ставке: https://scidar.kg.ac.rs/handle/123456789/11231
Назив: Ganglion Cell-Inner Plexiform Layer Thickness in Different Glaucoma Stages Measured by Optical Coherence Tomography
Аутори: Zivkovic M.
Dayanir V.
Zlatanović M.
Zlatanovic G.
Jaksic V.
Jovanovic P.
Radenkovic M.
Djordjevic Jocic J.
Stankovic Babic, Gordana
Jovanovic, Svetlana
Датум издавања: 2018
Сажетак: © 2017 S. Karger AG, Basel. Copyright: All rights reserved. Aim: To compare ganglion cell (GCL) and inner plexiform layer (IPL) thickness in patients at different stages of primary open-angle glaucoma (POAG), determine their sensitivity and specificity values, and correlate thickness values with mean deviations (MD). Methods: This prospective, cross- sectional study was conducted in a group of patients with confirmed POAG who were compared to an age- and gender-matched control group. Glaucomatous damage was classified according to the Hodapp-Parrish-Anderson scale: glaucoma stage 1 (early), glaucoma stage 2 (moderate), and glaucoma stage 3 (severe). The average, minimum, and all 6 sectoral (superotemporal, superior, superonasal, inferonasal, inferior, and inferotemporal) GCL + IPL thicknesses were measured and compared between groups. Results: The average GCL + IPL thickness of 154 eyes of 93 patients in glaucoma stages 1, 2, 3, and 94 eyes of 47 persons in the control group were 76.79 ± 8.05, 65.90 ± 7.92, 57.38 ± 10.00, and 86.01 ± 3.68 μm, respectively. There were statistically significant differences in the average, minimum, and all 6 sectoral GCL + IPL values among the groups. The areas under the receiver operating characteristic curve for average and minimum GCL + IPL thickness values were 0.93 and 0.94, respectively, sensitivity 91.5 and 88.3%, and specificity 98.9 and 100%, respectively. Both thickness values showed significant correlations with MD. Each micrometer decrease in the average GCL + IPL thickness was associated with a 0.54-dB loss in MD. Conclusion: GCL + IPL layer thickness is a highly specific and sensitive parameter in differentiating glaucomatous from healthy eyes showing progressive damage as glaucoma worsens. Loss of this layer is highly correlated with overall loss of visual field sensitivity.
URI: https://scidar.kg.ac.rs/handle/123456789/11231
Тип: article
DOI: 10.1159/000478052
ISSN: 0030-3747
SCOPUS: 2-s2.0-85028971666
Налази се у колекцијама:Faculty of Medical Sciences, Kragujevac

Број прегледа

445

Број преузимања

12

Датотеке у овој ставци:
Датотека Опис ВеличинаФормат 
PaperMissing.pdf
  Ограничен приступ
29.86 kBAdobe PDFСличица
Погледајте


Ставке на SCIDAR-у су заштићене ауторским правима, са свим правима задржаним, осим ако није другачије назначено.