Молимо вас користите овај идентификатор за цитирање или овај линк до ове ставке: https://scidar.kg.ac.rs/handle/123456789/11349
Назив: Cervical breaking point; A phenomenon unveiled during continuous controllable balloon dilatation
Аутори: Arsenijevic P.
Zivanovic, Aleksandar
Protrka, Zoran
Dimitrijevic, Aleksandra
Sorak, Marija
Vulovic, Tatjana
Vukcevic Globarevic G.
Vilendečić Z.
Andric B.
Arsenijevic, Slobodan
Датум издавања: 2018
Сажетак: © 2018 S.O.G. Canada Inc.All rights reserved. Introduction: Based on the characteristics of the internal cervical os and the cervix as a whole, during continuous controllable balloon dilatation, it can be said that the uterine cervix behaves as a sphincter, although it does not have the anatomical structure of a sphincter. Material and Methods: The system for continuous and controllable balloon dilatation is based on the hydraulic balloon dilator. The main advantage of the continuous and controllable balloon dilatation is that it provides the physician with the ability to monitor and control the process of cervical dilatation. This study included 42 patients, in whom the dilatation process was monitored and analysed prior to the termination of an unwanted pregnancy. Statistical analyses were performed using SPSS software. A normal distribution of continuous data was tested using the Kolmogorov-Smirnov test. The correlation between observed parameters was analysed using Pearson's and Spearman's correlation coefficients. Results: During dilatation with continuous and controllable balloon dilatation system, a sudden drop in pressure and volume of the fluid in the balloon extension occurred. This phenomenon was labelled as the breaking point of the cervix, or the point when the cervix stops resisting dilatation. There was no statistically significant correlation between the cervical breaking point and the number of previous births or the number of previous miscarriages or abortions. Discussion: The uterine cervix behaves as a sphincter during continuous and controllable balloon dilatation, which is verified by the existence of a cervical breaking point. The breaking point values did not vary with the number of previous cervical dilatations, whether artificial or physiological.
URI: https://scidar.kg.ac.rs/handle/123456789/11349
Тип: article
DOI: 10.12891/ceog4227.2018
ISSN: 0390-6663
SCOPUS: 2-s2.0-85058849177
Налази се у колекцијама:Faculty of Medical Sciences, Kragujevac

Број прегледа

127

Број преузимања

11

Датотеке у овој ставци:
Датотека Опис ВеличинаФормат 
PaperMissing.pdf
  Ограничен приступ
29.86 kBAdobe PDFСличица
Погледајте


Ставке на SCIDAR-у су заштићене ауторским правима, са свим правима задржаним, осим ако није другачије назначено.