Please use this identifier to cite or link to this item:
https://scidar.kg.ac.rs/handle/123456789/11513
Title: | Analysis of the Measurement System and Optimization of the Measurement Procedure for Detection of Thermal Memory Effects by Photoacoustic Experiments |
Authors: | Todosijević, Slobodan Šoškić, Zlatan Stojanovic, Zoran Galovic, Slobodanka |
Issue Date: | 2017 |
Abstract: | © 2017, Springer Science+Business Media New York. Experimental verification of thermal memory effects represents a challenge that is important from both fundamental and practical points of view. Recent theoretical studies suggest that the thermal memory effect should lead to thermal resonances in the modulation frequency characteristics of photoacoustic response. Therefore, studies of thermal resonances in photoacoustic response represent an alternative for detection of the thermal memory effect and measurement of thermal memory properties. Since the resonances were not observed, this paper analyzes standard measurement setups and shows that the experimental technique should be optimized to provide a better chance of detection of thermal memory effects by photoacoustic measurements. The results show that a proper selection of modulation frequencies and the knowledge of the approximate transfer function of the electronic part of the photoacoustic measurement system are prerequisites for detection of thermal resonances in the modulation frequency characteristics of photoacoustic response. |
URI: | https://scidar.kg.ac.rs/handle/123456789/11513 |
Type: | article |
DOI: | 10.1007/s10765-017-2215-9 |
ISSN: | 0195-928X |
SCOPUS: | 2-s2.0-85015745154 |
Appears in Collections: | Faculty of Mechanical and Civil Engineering, Kraljevo |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
PaperMissing.pdf Restricted Access | 29.86 kB | Adobe PDF | View/Open |
Items in SCIDAR are protected by copyright, with all rights reserved, unless otherwise indicated.