Молимо вас користите овај идентификатор за цитирање или овај линк до ове ставке: https://scidar.kg.ac.rs/handle/123456789/12335
Назив: Perfomance of single-stage rotating biological contactor with supplemental aeration
Аутори: Cvetković, Dragan
Sustersic, Vanja
Gordić, Dušan
Bojic, Milorad
Stosic I.
Датум издавања: 2014
Сажетак: The aim of this paper was to study the performance of a single-stage rotating biological contactor with supplemental aeration in terms of removal efficiency of organic and nitrogen content. Research was based on fifteen samples collected during the four year period. The wastewater was low strength with maximal measured concentration of 362 mg COD/l, 100 mg NH4/l, and 324 mg TSS/L. The maximal measured removal efficiency of COD (chemical oxygen demand) and TSS (total suspend solids) were 71% and 56%, respectively. The high rate of nitrogen removal was achieved using supplemental aeration. The removal efficiency of NH4, NO2and NO3 were 83%, 60% and 52%, respectively.
URI: https://scidar.kg.ac.rs/handle/123456789/12335
Тип: article
DOI: 10.30638/eemj.2014.072
ISSN: 1582-9596
SCOPUS: 2-s2.0-84903775854
Налази се у колекцијама:Faculty of Engineering, Kragujevac
Institute for Information Technologies, Kragujevac