Назив: | Results of the first national indoor radon survey performed in Serbia |
Аутори: | Savković Eremić, Marija Udovicic, Vladimir Maletić D. Pantelic, Gordana Ujic, Predrag Celikovic, Igor Forkapic S. Marković, Vladimir Arsić V. Ilic Zivojinovic J. Markoski B. |
Датум издавања: | 2020 |
Сажетак: | © 2020 Society for Radiological Protection. Published on behalf of SRP by IOP Publishing Limited. All rights reserved. The first step in every systematic approach to investigating population exposure to radon on a national level is to perform a comprehensive indoor radon survey. Based on general knowledge of the radon levels in Serbia and corresponding doses, the results obtained from a national indoor radon survey would allow policymakers to decide whether it is necessary to establish a national radon programme. For this reason, Serbia initiated work on a national radon action plan (RAP) in 2014 when it was decided to carry out the first national indoor radon survey. The responsibility for establishing the RAP in Serbia is that of the national regulatory body in the field of radiation protection-the Serbian Radiation and Nuclear Safety and Security Directorate (SRBATOM), formerly known as the Serbian Radiation Protection and Nuclear Safety Agency. The first national indoor radon survey was supported by the International Atomic Energy Agency (IAEA) through a Technical Cooperation Programme. Thanks to the IAEA, we received 6000 passive radon devices based on track-etched detectors. In addition, in order to ensure technical support for the project, SRBATOM formed a task force made up of expert radon representatives from national research institutions. This paper presents a thorough description of the sampling design of the first Serbian indoor radon survey. It also presents the results of the national indoor radon survey, including descriptive statistics and testing of the distribution of the obtained results for log-normality. Based on GPS coordinates, indoor radon data were projected onto a map of 10 km × 10 km grid cells. Two values were calculated for each cell to create two distinct maps. One map shows the arithmetic mean value of indoor radon concentration per grid cell, and the other map shows the number of radon detectors per grid cell used for the calculation of mean values. |
URI: | https://scidar.kg.ac.rs/handle/123456789/12834 |
Тип: | article |
DOI: | 10.1088/1361-6498/ab749e |
ISSN: | 0952-4746 |
SCOPUS: | 2-s2.0-85085713577 |
Налази се у колекцијама: | Faculty of Science, Kragujevac |
Датотеке у овој ставци:
Датотека | Опис | Величина | Формат | |
---|---|---|---|---|
PaperMissing.pdf Ограничен приступ | 29.86 kB | Adobe PDF | Погледајте |
Ставке на SCIDAR-у су заштићене ауторским правима, са свим правима задржаним, осим ако није другачије назначено.