Молимо вас користите овај идентификатор за цитирање или овај линк до ове ставке: https://scidar.kg.ac.rs/handle/123456789/19151
Назив: EXERGY EFFICIENCY OF PANEL HEATING SYSTEMS AT DIFFERENT HEAT SOURCE
Аутори: Cvetković, Dragan
Bojic, Milorad
Rankovic, Vesna
Nikolic, Danijela
Skerlic, Jasmina
Датум издавања: 2013
Сажетак: This paper aims to compare the exergy efficiency of panel heating system using different energy sources. Natural gas and geothermal heat pump are used as energy sources. Floor panels, wall panels, ceiling panels, and floor-ceiling panels are used as panel heating systems. The analysed house is located in Kragujevac, Serbia. Also, this research is the part of the project "Development of a net-zero-energy house“. The operation of these panels is simulated by software EnergyPlus that is product of Lawrence Berkley Laboratory in USA.
URI: https://scidar.kg.ac.rs/handle/123456789/19151
Тип: conferenceObject
Налази се у колекцијама:Faculty of Engineering, Kragujevac

Број прегледа

20

Број преузимања

4

Датотеке у овој ставци:
Датотека Опис ВеличинаФормат 
DN DC KGH 2013.pdf646.54 kBAdobe PDFСличица
Погледајте


Ставке на SCIDAR-у су заштићене ауторским правима, са свим правима задржаним, осим ако није другачије назначено.