Молимо вас користите овај идентификатор за цитирање или овај линк до ове ставке:
https://scidar.kg.ac.rs/handle/123456789/19203
Назив: | Hydraulic calculation of power plant for mixture transport from the big depths |
Аутори: | Milovanovic, Dobrica Nikolic, Danijela Jovicic, Nebojsa |
Датум издавања: | 2002 |
Сажетак: | In the pump plant application it is often necessary to transport fluid from the depths that are greater than pump suction height. For that purpose it is not always possible to use mamut pumps because of solid ingredients in the fluid or low efficiencies. In that case one can use plants that combine turbo pumps and ejectors. In principle, turbo pump is placed above liquid level, while ejector is sunk into the liquid. In this paper is presented the calculation method for mentioned plant. Different configuration of turbo pumps andlejectors are considered inlorder to define conditions for plant efficiency increase. 1 |
URI: | https://scidar.kg.ac.rs/handle/123456789/19203 |
Тип: | conferenceObject |
Налази се у колекцијама: | Faculty of Engineering, Kragujevac |
Датотеке у овој ставци:
Датотека | Опис | Величина | Формат | |
---|---|---|---|---|
DEMI 2002.pdf | 4.53 MB | Adobe PDF | Погледајте |
Ставке на SCIDAR-у су заштићене ауторским правима, са свим правима задржаним, осим ако није другачије назначено.