Молимо вас користите овај идентификатор за цитирање или овај линк до ове ставке: https://scidar.kg.ac.rs/handle/123456789/19281
Назив: DOSIMETRIC COMPARISON OF VMAT AND 3D CONFORMAL RADIOTHERAPY IN PREOPERATIVE RECTAL CANCER
Аутори: Miladinovic, Tatjana B.
Miladinović, Aleksandar
Pavlović, Nina
Nikezic, Dragoslav
Krstic, Dragana
Zivkovic, Milena
Датум издавања: 2021
Сажетак: The standard procedure in treating rectum cancer is surgical intervention, but presurgical chemotherapy and radiotherapy lead to a lower rate of localized recidives. Our study compared the results obtained by two techniques of radiation treatment planning (RTP) in radiotherapy, which patients received in the preoperative course of rectum cancer treatment, Volumetric Modulated Arc Therapy (VMAT) and field-in-field three-dimensional conformal radiotherapy (FIF 3D-CRT). We analyzed better coverage of the planning target volume (PTV) and better protection of organs from risk (OAR): bladder, bowel, left femoral head, and right femoral head results and monitor unit (MU). Also, we analyzed the target volume coverage indicators included homogeneity index (HI), and conformity index (CI). Selected five patients were treated in University Clinical Center Kragujevac during 2020. The two types of techniques for making radiotherapy plans, mentioned above, were designed for each patient using the same CT scans. All plans were done on the treatment planning system ECLIPSEVersion 15.6 (Varian). The prescribed dose for all patients was 50 Gy in 25 fractions. The first arc was planned in the clockwise direction and the second in the counter clockwise direction. FIF 3D-CRT plans were obtained by using fields from four different directions with the same isocenter. It was obtained that VMAT plans, compared to the FIF 3D-CRT, achieved better coverage of the PTV (D95%), better heterogeneity, and conformity. Protection for OAR such as the bladder, femoral heads, and small bowel is much better than that given by FIF 3D-CRT plans. However, the number of MU calculated by FIF 3D-CRT is almost twice lower compared to VMAT.
URI: https://scidar.kg.ac.rs/handle/123456789/19281
Тип: conferenceObject
Налази се у колекцијама:Institute for Information Technologies, Kragujevac

Број прегледа

339

Број преузимања

11

Датотеке у овој ставци:
Датотека Опис ВеличинаФормат 
1st_ICCBIKG_Dosimetric comparison of VMAT and 3D conformal radiotherapy.pdf526.43 kBAdobe PDFСличица
Погледајте


Ставке на SCIDAR-у су заштићене ауторским правима, са свим правима задржаним, осим ако није другачије назначено.