Молимо вас користите овај идентификатор за цитирање или овај линк до ове ставке: https://scidar.kg.ac.rs/handle/123456789/23403
Назив: Methodology for measuring pressure at the contact surface between a column footing model and a soil layer limited by a rigid base using Earth pressure cells
Аутори: Mihajlović, Stefan
Bižić, Milan
Despotovic, Iva
Bojković, Jovana
Janićijević, Marijana
Часопис: Triennial International Scientific Conference Engineering Today (12 ; 2026 ; Vrnjačka Banja)
Датум издавања: 2026
Сажетак: The design of all building structures largely depends on the foundation support system, i.e., the relevant actions for structural design depend on soil–structure interaction. This paper describes a methodology for measuring pressures at the contact surface between a column footing model and a soil layer limited by a rigid base using earth pressure cells. The purpose of the research is to assess the reliability of the obtained results representing contact stress distributions between the interacting components under laboratory conditions. The concept of a reduced-scale footing model is presented, along with the procedure for preparing and installing earth pressure cells in the soil, with special emphasis on their position and data acquisition method. The main factors affecting measurement accuracy are also discussed, including soil characteristics, geometric and material properties of the tested footing model. The aim of this paper is to define an experimental procedure for a footing model and a soil layer limited by a rigid base that can serve as a basis for further experimental research and validation of numerical models. The reliability control of the measured contact stresses using earth pressure cells is based on comparison with analytical results. This experimental study examined contact pressures between a footing model and compacted sand using earth pressure cells. Measured pressures deviated significantly from calculated uniform values in the first test (48.3%) due to installation-induced soil disturbance, but improved to an acceptable 9.2% in the third test with proper surface preparation. The load–pressure relationship remained nearly linear across all measurements, consistent with sensor specifications.
URI: https://scidar.kg.ac.rs/handle/123456789/23403
Тип: conferenceObject
DOI: 10.46793/ET26.G07M
Налази се у колекцијама:Faculty of Mechanical and Civil Engineering, Kraljevo

Датотеке у овој ставци:
Датотека Опис ВеличинаФормат 
et2026-g07.pdf2.6 MBAdobe PDFПогледајте


Ова ставка је заштићена лиценцом Креативне заједнице Creative Commons