Please use this identifier to cite or link to this item:
https://scidar.kg.ac.rs/handle/123456789/22842Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Karamarkovic, Rade | - |
| dc.contributor.author | Marjanović, Milan | - |
| dc.contributor.author | Nikolić, Miloš | - |
| dc.contributor.author | Todorović, Dušan | - |
| dc.contributor.author | Obradović, Marko | - |
| dc.date.accessioned | 2025-12-24T14:14:20Z | - |
| dc.date.available | 2025-12-24T14:14:20Z | - |
| dc.date.issued | 2025 | - |
| dc.identifier.citation | Karamarković, R., Marjanović, M., Nikolić, M., Todorović, D., Obradović, M., Active condensation in hot and superheated water boilers, Book of abstracts of 38th Scientific Conference Procesing 2025, ISBN:978-86-85535-21-5, Negotin, Serbia | en_US |
| dc.identifier.isbn | 978-86-85535-21-5 | en_US |
| dc.identifier.uri | https://scidar.kg.ac.rs/handle/123456789/22842 | - |
| dc.description.abstract | Return temperatures in hot and superheated water boilers are frequently higher than the corresponding flue gas dew point temperature. To utilize the fuel’s higher heating value in such boilers, active condensation (AC) systems must be employed. However, these systems require additional energy to transfer heat from below the dew point to above the return water temperature. This paper analyzes three AC systems in three case studies: (i) a compressor heat pump (HP) in a boiler room supplying a hot water district heating (DH) system; (ii) a superheated water DH system fueled by natural gas, using a flue gas condenser coupled with a compressor HP-based AC system; and (iii) the same system as (ii) but with an absorption HP. The case studies are based on experimental investigations of DH systems in Loznica (i) and Kraljevo (ii and iii). Numerical models were developed using experimental data and findings from other researchers, combined with material and energy balances. The results address the following key questions: (i) When is AC implementation economically feasible? (ii) What type of HP should be used, and under what conditions? (iii) What HP design specifications are required? (iv) What is the optimal flue gas temperature for AC systems? (v) Under what circumstances is coupling flue gas condensation with AC viable? (vi) When is an absorption HP economically justified? | en_US |
| dc.publisher | Beograd : Savez mašinskih i elektrotehničkih inženjera i tehničara Srbije (SMEITS), Društvo za procesnu tehniku | en_US |
| dc.relation.ispartof | Zbornik rezimea radova [pisanih za] 38. Međunarodni kongres o procesnoj industriji, PROCESING '25, [(29. i 30. maj 2025)] Book of Abstracts | en_US |
| dc.subject | boiler | en_US |
| dc.subject | higher heating value | en_US |
| dc.subject | active condensation | en_US |
| dc.subject | heat pump | en_US |
| dc.subject | model | en_US |
| dc.title | Active condensation in hot and superheated water boilers | en_US |
| dc.title.alternative | Primena aktivne kondenzacije kod toplovodnih i vrelovodnih kotlova | en_US |
| dc.type | conferenceObject | en_US |
| dc.description.version | Published | en_US |
| dc.type.version | PublishedVersion | en_US |
| dc.source.conference | Procesing 2025 | en_US |
| Appears in Collections: | Faculty of Technical Sciences, Čačak | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| Karamarković, M. - Procesing-25.pdf | 3.93 MB | Adobe PDF | ![]() View/Open |
Items in SCIDAR are protected by copyright, with all rights reserved, unless otherwise indicated.

