dc.identifier.citationKaramarković, R., Marjanović, M., Nikolić, M., Todorović, D., Obradović, M., Active condensation in hot and superheated water boilers, Book of abstracts of 38th Scientific Conference Procesing 2025, ISBN:978-86-85535-21-5, Negotin, Serbiaen_US
dc.identifier.isbn978-86-85535-21-5en_US
dc.identifier.urihttps://scidar.kg.ac.rs/handle/123456789/22842-
dc.description.abstractReturn temperatures in hot and superheated water boilers are frequently higher than the corresponding flue gas dew point temperature. To utilize the fuel’s higher heating value in such boilers, active condensation (AC) systems must be employed. However, these systems require additional energy to transfer heat from below the dew point to above the return water temperature. This paper analyzes three AC systems in three case studies: (i) a compressor heat pump (HP) in a boiler room supplying a hot water district heating (DH) system; (ii) a superheated water DH system fueled by natural gas, using a flue gas condenser coupled with a compressor HP-based AC system; and (iii) the same system as (ii) but with an absorption HP. The case studies are based on experimental investigations of DH systems in Loznica (i) and Kraljevo (ii and iii). Numerical models were developed using experimental data and findings from other researchers, combined with material and energy balances. The results address the following key questions: (i) When is AC implementation economically feasible? (ii) What type of HP should be used, and under what conditions? (iii) What HP design specifications are required? (iv) What is the optimal flue gas temperature for AC systems? (v) Under what circumstances is coupling flue gas condensation with AC viable? (vi) When is an absorption HP economically justified?en_US
dc.publisherBeograd : Savez mašinskih i elektrotehničkih inženjera i tehničara Srbije (SMEITS), Društvo za procesnu tehnikuen_US
dc.relation.ispartofZbornik rezimea radova [pisanih za] 38. Međunarodni kongres o procesnoj industriji, PROCESING '25, [(29. i 30. maj 2025)] Book of Abstractsen_US
dc.subjectboileren_US
dc.subjecthigher heating valueen_US
dc.subjectactive condensationen_US
dc.subjectheat pumpen_US
dc.subjectmodelen_US
dc.titleActive condensation in hot and superheated water boilersen_US
dc.title.alternativePrimena aktivne kondenzacije kod toplovodnih i vrelovodnih kotlovaen_US
dc.typeconferenceObjecten_US
dc.description.versionPublisheden_US
dc.type.versionPublishedVersionen_US
dc.source.conferenceProcesing 2025en_US
Appears in Collections:Faculty of Technical Sciences, Čačak

Page views(s)

30

Downloads(s)

9

Files in This Item:
File Description SizeFormat 
Karamarković, M. - Procesing-25.pdf3.93 MBAdobe PDFThumbnail
View/Open


Items in SCIDAR are protected by copyright, with all rights reserved, unless otherwise indicated.