Please use this identifier to cite or link to this item:
https://scidar.kg.ac.rs/handle/123456789/8403
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.rights.license | openAccess | - |
dc.contributor.author | Koprivica, Branko | - |
dc.contributor.author | Chwastek, Krzysztof | - |
dc.contributor.author | Milunović Koprivica, Sandra | - |
dc.date.accessioned | 2020-09-19T15:39:12Z | - |
dc.date.available | 2020-09-19T15:39:12Z | - |
dc.date.issued | 2019 | - |
dc.identifier.issn | 0033-2097 | - |
dc.identifier.uri | https://scidar.kg.ac.rs/handle/123456789/8403 | - |
dc.description.abstract | © 2019, Wydawnictwo SIGMA-NOT. All rights reserved. The aim of this paper is to present experimental results on the short-circuit and load test of the single-phase transformer at low frequencies. The paper gives information on PC based measurement setup and presents the results of measurement of primary and secondary voltages and currents and electric power of the transformer. Also, a proper discussion of the results obtained is given in the paper. | - |
dc.rights | info:eu-repo/semantics/openAccess | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | - |
dc.source | Przeglad Elektrotechniczny | - |
dc.title | Short-circuit and load operation of single-phase transformer at low frequencies | - |
dc.type | article | - |
dc.identifier.doi | 10.15199/48.2019.07.05 | - |
dc.identifier.scopus | 2-s2.0-85069802929 | - |
Appears in Collections: | Faculty of Technical Sciences, Čačak |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
10.15199-48.2019.07.05.pdf | 540.8 kB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License