Please use this identifier to cite or link to this item:
https://scidar.kg.ac.rs/handle/123456789/11157
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.rights.license | restrictedAccess | - |
dc.contributor.author | Petrovic Savic, Suzana | - |
dc.contributor.author | Ristic, Branko | - |
dc.contributor.author | Jovanovic, Zorica | - |
dc.contributor.author | Matic, Aleksandar | - |
dc.contributor.author | Prodanovic, Nikola | - |
dc.contributor.author | anwer, nabil | - |
dc.contributor.author | Qiao L. | - |
dc.contributor.author | Devedzic, Goran | - |
dc.date.accessioned | 2021-04-20T17:38:19Z | - |
dc.date.available | 2021-04-20T17:38:19Z | - |
dc.date.issued | 2018 | - |
dc.identifier.issn | 2234-7593 | - |
dc.identifier.uri | https://scidar.kg.ac.rs/handle/123456789/11157 | - |
dc.description.abstract | © 2018, Korean Society for Precision Engineering and Springer-Verlag GmbH Germany, part of Springer Nature. In this paper, a method of parameterisation of a proximal femur model is presented. The created model retains all the anatomical and morphological features of a realistic model. The parametric model of the femur, the so-called master model, is defined by establishing a relation between appropriate femoral regions which extend along the parametrically described axis of the femur. An initial 3D model of the femur is segmented from the CT image and further parameterized to a master model with the potential for customization, i.e. for adaptation to patient-specific values using X-ray images, still maintaining precise anatomical consistency. The first step towards the femur customization is the contour extraction of different types of tissues represented in X-ray images. As medical images can be blurry, image processing was carried out and a Canny edge detector operator was applied. The numerical values of the parameters were determined by manual measuring of defined regions on an X-ray image. The variability testing was performed on 12 femurs. The proposed model can greatly contribute to preoperative planning, implant selection, as well as to the overall shortening of intervention time. | - |
dc.rights | info:eu-repo/semantics/restrictedAccess | - |
dc.rights | info:eu-repo/semantics/restrictedAccess | - |
dc.source | International Journal of Precision Engineering and Manufacturing | - |
dc.title | Parametric Model Variability of the Proximal Femoral Sculptural Shape | - |
dc.type | article | - |
dc.identifier.doi | 10.1007/s12541-018-0124-x | - |
dc.identifier.scopus | 2-s2.0-85049560738 | - |
Appears in Collections: | Faculty of Engineering, Kragujevac Faculty of Medical Sciences, Kragujevac |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
PaperMissing.pdf Restricted Access | 29.86 kB | Adobe PDF | View/Open |
Items in SCIDAR are protected by copyright, with all rights reserved, unless otherwise indicated.