dc.description.abstract© 2017 Elsevier B.V. District heating system brings with it the problem of achieving a fair billing service for heating of apartment buildings in the case of uneven temperature in them. The problem is most pronounced when the individual apartments are completely excluded from the heating system of the building. The model of an existing building with 24 apartments was simulated in the software EnergyPlus, for different characteristics of the thermal envelope and different conditions of use, when the apartment with the lowest energy consumption is excluded from the heating system. It was simulated the exclusion of this apartment in which people are present and the lights and electrical appliances are turned on and in which there is no presence of people and electricity consumption (the apartment is empty). As a measure of energy flow between unheated and adjacent apartments, the parameter “stolen” energy is defined. The results of the conducted simulations show that the stolen energy is reduced by the exterior and interior insulation of the building. In this paper, data on energy flow when there is interior insulation in apartments, in particular according to the current regulations in Serbia, are especially analyzed. The results show that, depending on the case and scenario, the stolen energy ranges from 27.23 to 7.97 kWh/m2. The insulation of interior walls of the building can significantly mitigate the problem of energy flow due to temperature differences between apartments.-
dc.rightsrestrictedAccess-
dc.sourceEnergy and Buildings-
dc.titleInfluence of an unheated apartment on the heating consumption of residential building considering current regulations—Case of Serbia-
dc.typearticle-
dc.identifier.doi10.1016/j.enbuild.2017.09.006-
dc.identifier.scopus2-s2.0-85029171177-
Appears in Collections:Faculty of Engineering, Kragujevac

Page views(s)

155

Downloads(s)

10

Files in This Item:
File Description SizeFormat 
PaperMissing.pdf
  Restricted Access
29.86 kBAdobe PDFThumbnail
View/Open


Items in SCIDAR are protected by copyright, with all rights reserved, unless otherwise indicated.