Молимо вас користите овај идентификатор за цитирање или овај линк до ове ставке: https://scidar.kg.ac.rs/handle/123456789/13891
Пун извештај метаподатака
Поље DC-а ВредностЈезик
dc.rights.licenserestrictedAccess-
dc.contributor.authorMarković, Vladimir-
dc.contributor.authorStajić, Jelena-
dc.contributor.authorMilenković, Biljana-
dc.contributor.authorStevanović, Nenad-
dc.date.accessioned2022-02-02T17:29:28Z-
dc.date.available2022-02-02T17:29:28Z-
dc.date.issued2022-
dc.identifier.issn0969-806X-
dc.identifier.urihttps://scidar.kg.ac.rs/handle/123456789/13891-
dc.description.abstractCylindrical diffusion chamber with solid state nuclear track detector placed at the bottom of the chamber is frequently used device for measuring radon concentration in dwellings. In this work, the diffusion chamber with CR-39 detector was modeled to determine track distribution on the lateral (cylinder) wall of the chamber and compare track density between cylinder wall and bottom. Model is based on the diffusion, deposition and decay of radon and its progeny in diffusion chamber. Equations for criteria of track visibility and track density were derived. Along with theoretical model, measurements were performed to verify the theoretical results. Three different chambers with CR-39 detectors slabs attached along the cylinder wall were investigated. It was found that alpha track density on cylinder wall is not uniform and depends on the shape and size of the chamber. Deviation of track density along cylinder wall was up to 30% for chambers used in this work. Sensitivity of the cylinder wall was found to be almost the same as the sensitivity of the bottom. In comparison with the experiment, theoretical results give good predictions. Along with previous results of the authors where bottom track density was modeled, presented model can be used for calibration and optimization of the diffusion chambers used for radon measurements.-
dc.rightsinfo:eu-repo/semantics/restrictedAccess-
dc.sourceRadiation Physics and Chemistry-
dc.titleAlpha track distribution on lateral wall of cylindrical radon diffusion chamber-
dc.typearticle-
dc.identifier.doi10.1016/j.radphyschem.2021.109873-
dc.identifier.scopus2-s2.0-85119288261-
Налази се у колекцијама:Faculty of Science, Kragujevac
Institute for Information Technologies, Kragujevac

Број прегледа

1392

Број преузимања

32

Датотеке у овој ставци:
Датотека Опис ВеличинаФормат 
PaperMissing.pdf
  Ограничен приступ
29.86 kBAdobe PDFСличица
Погледајте


Ставке на SCIDAR-у су заштићене ауторским правима, са свим правима задржаним, осим ако није другачије назначено.