Please use this identifier to cite or link to this item: https://scidar.kg.ac.rs/handle/123456789/15609
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKrstic, Dragana-
dc.contributor.authorNikezic, Dragoslav-
dc.contributor.authorJeremic M.-
dc.contributor.authorDolićanin E.-
dc.contributor.authorMiladinovic, Tatjana B.-
dc.contributor.authorZivkovic, Milena-
dc.date.accessioned2023-02-08T15:25:18Z-
dc.date.available2023-02-08T15:25:18Z-
dc.date.issued2023-
dc.identifier.issn0969-8043-
dc.identifier.urihttps://scidar.kg.ac.rs/handle/123456789/15609-
dc.description.abstractAbsorbed doses in uterus during brachytherapy were calculated with MCNP in relevant points and compared with planning system for one patients. MCNP was applied with two different humanoid phantoms in input, ORNL and voxel models, which represent human body in mathematical way. Good agreement between both phantoms, as well as, between MCNP and planning system were found. In addition the doses in critical organs (bladder and colon in this kind of therapy), were calculated and compared with maximal doses in these organs obtained from planning system for 15 other patients. MCNP doses agree well with planning system in points of uterus for those 15 patients, where radioactive source is used to apply. However, there are systematical discrepancies between doses in colon and bladder obtained by MCNP and planning system.-
dc.sourceApplied Radiation and Isotopes-
dc.titleComparison between MCNP and planning system in brachytherapy of cervical cancer-
dc.typearticle-
dc.identifier.doi10.1016/j.apradiso.2022.110614-
dc.identifier.scopus2-s2.0-85143979954-
Appears in Collections:Faculty of Science, Kragujevac
Institute for Information Technologies, Kragujevac

Page views(s)

102

Downloads(s)

3

Files in This Item:
File Description SizeFormat 
PaperMissing.pdf
  Restricted Access
29.86 kBAdobe PDFThumbnail
View/Open


Items in SCIDAR are protected by copyright, with all rights reserved, unless otherwise indicated.