Молимо вас користите овај идентификатор за цитирање или овај линк до ове ставке: https://scidar.kg.ac.rs/handle/123456789/18117
Пун извештај метаподатака
Поље DC-а ВредностЈезик
dc.contributor.authorMatic, Aleksandar-
dc.contributor.authorRistic, Branko-
dc.contributor.authorDevedzic, Goran-
dc.contributor.authorPetrovic Savic, Suzana-
dc.contributor.authorCukovic, Sasa-
dc.date.accessioned2023-06-07T06:42:33Z-
dc.date.available2023-06-07T06:42:33Z-
dc.date.issued2013-
dc.identifier.urihttps://scidar.kg.ac.rs/handle/123456789/18117-
dc.description.abstractAnterior cruciate ligament (ACL) deficiency is the common injury for people involved in sports. ACL injuries directly affect on the knee joint kinematic and function whereby makes the simplest everyday activities difficult (such as walking, stairs climbing, etc). The aim of this study is to show new objective method for determining knee instability and evaluate the success of the reconstructive surgery. Kinematic parameters that indicate this type of injury are anterior - posterior (AP) translation and internal - external (IE) rotation. In examining ACL deficiency twenty-nine patients with this type of injury were involved. Kinematic data were collected by using 3D OptiTrack system. The measurements were made the day before and six weeks after reconstructive operation. ACL deficiency decision making was based on descriptive Lachman test and machine learning algorithm. Every injured patient underwent ACL reconstruction with hamstring autograft and anteromedial portal technique. Results show that higher values of the kinematic parameters occur in the moment of the support loss of the gait cycle. After reconstructive surgery, these values decrease and they are approximately the same to the values of the contralateral healthy knee.en_US
dc.language.isoenen_US
dc.rightsinfo:eu-repo/semantics/openAccess-
dc.source4th Balkan congress of arthroscopy, sports traumatology and knee surgery, Novi Sad ,Srbija, 2013en_US
dc.subjectACL reconstructionen_US
dc.subjecthamstring autograften_US
dc.subjectkinematic parametersen_US
dc.titleAP Тranslation and IE Rotation Reduction Analysis By Using 3D Optitrack Systemen_US
dc.typeotheren_US
dc.description.versionPublisheden_US
dc.type.versionPublishedVersionen_US
Налази се у колекцијама:Faculty of Engineering, Kragujevac

Број прегледа

851

Број преузимања

23

Датотеке у овој ставци:
Датотека Опис ВеличинаФормат 
B. Ristic et al.pdf196.68 kBAdobe PDFСличица
Погледајте


Ставке на SCIDAR-у су заштићене ауторским правима, са свим правима задржаним, осим ако није другачије назначено.