Please use this identifier to cite or link to this item: https://scidar.kg.ac.rs/handle/123456789/19280
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPavlović, Nina-
dc.contributor.authorMiladinovic, Tatjana B.-
dc.contributor.authorStojanović, Darko-
dc.contributor.authorMiladinović, Aleksandar-
dc.contributor.authorJeremić, Marija-
dc.date.accessioned2023-11-03T12:05:51Z-
dc.date.available2023-11-03T12:05:51Z-
dc.date.issued2021-
dc.identifier.isbn978-86-82172-01-7en_US
dc.identifier.urihttps://scidar.kg.ac.rs/handle/123456789/19280-
dc.description.abstractTo identify the best treatment technique for patients with left-sided breast cancer, we compared plans obtained with a hybrid intensity-modulated radiation therapy (hIMRT) and conventional threedimensional conformal radiation therapy (3D-CRT). Dosimetric indices for PTVs and OARs were calculated. Also, the dose coverage, homogeneity index, conformity index of the target, and the dose volumes of critical structures were analyzed. A sample of seven patients who were selected randomly treated in University Clinical Center Kragujevac between 2019 and 2020 was selected for the study. Therapy plans for both techniques were made with an ECLIPSE treatment planning system for each patient based on the same images and contours. The hybrid IMRT technique consists of two static opposed tangential fields and four optimized IMRT fields (dose ratio 70:30). For 3D-CRT planning, one isocenter with half-beam blocked tangential fields with wedges was used. All treatment plans were generated with 6 MV photon beam. Hybrid IMRT plans compared to the 3D-CRT resulted in better dose delivered to 95% (D95) of the planning target volume (PTV) and better heterogeneity HI and conformity CI. Protection for critical organs such as the heart, lungs, and contralateral breast is slightly worse than those obtained by 3D-CRT.en_US
dc.language.isoenen_US
dc.rightsinfo:eu-repo/semantics/openAccess-
dc.source1st International Conference on Chemo and BioInformatics, Kragujevac, October 26-27, 2021 Serbiaen_US
dc.subjectbreast canceren_US
dc.subjectthree-dimensional conformal radiotherapy (3D-CRT)en_US
dc.subjecthybrid intensitymodulated radiation therapy (hIMRT)en_US
dc.titleHYBRID IMRT RADIATION TECHNIQUE COMPARISON WITH 3D-CRT FOR LEFT-SIDED WHOLE BREAST CANCERen_US
dc.typeconferenceObjecten_US
dc.description.versionPublisheden_US
dc.type.versionPublishedVersionen_US
Appears in Collections:Institute for Information Technologies, Kragujevac

Page views(s)

334

Downloads(s)

12

Files in This Item:
File Description SizeFormat 
1st_ICCBIKG_Hybrid IMRT radiation technique comparison.pdf444.72 kBAdobe PDFThumbnail
View/Open


Items in SCIDAR are protected by copyright, with all rights reserved, unless otherwise indicated.