Please use this identifier to cite or link to this item: https://scidar.kg.ac.rs/handle/123456789/19652
Full metadata record
DC FieldValueLanguage
dc.contributor.authorTurina, Dušan-
dc.contributor.authorMilosevic, Bojan-
dc.contributor.authorKostić, Aleksandar-
dc.contributor.authorPenava, Davorin-
dc.contributor.authorPetrović, Žarko-
dc.date.accessioned2023-12-15T13:40:40Z-
dc.date.available2023-12-15T13:40:40Z-
dc.date.issued2023-
dc.identifier.isbn978-86-88601-80-1en_US
dc.identifier.urihttps://scidar.kg.ac.rs/handle/123456789/19652-
dc.description.abstractEarthquakes in the vicinity of urban areas affect a large number of buildings, of different vulnerability classes, built over a long period of time and in accordance with the building codes of that period. Most often, these are masonry or concrete family and multi-storey residential buildings, a large part of which does not have sufficient earthquake resistance in accordance with the current building codes i.e., EN1998-1. When inspecting damaged buildings after earthquakes, it is usually observed that the damage grade is greater than expected considering the year of construction. One of the reasons is additions to the existing building structure, such as the expansion and/or elevation of the building. Building owners mostly do this without design, while not being aware of how they affect the earthquake behaviour of the building. Using a masonry multi-story residential building as a case study, the assessment of the earthquake behaviour of the building using a non-linear static pushover method is performed, considering the possibility of adding additional storeys to the building, with the condition of not affecting the earthquake resistance in any harmful way.en_US
dc.language.isoenen_US
dc.subjectresidential masonry buildingen_US
dc.subjectreconstructionen_US
dc.subjectbuilding upgradingen_US
dc.subjectnonlinear static analysisen_US
dc.subjectearthquake performanceen_US
dc.titleA CASE STUDY OF RECONSTRUCTION OF A RESIDENTIAL MASONRY BUILDING: DOES UPGRADING A BUILDING ADVERSELY AFFECTS ITS EARTHQUAKE PERFORMANCE?en_US
dc.typeconferenceObjecten_US
dc.description.versionPublisheden_US
dc.relation.conferenceTHE INTERNATIONAL CONFERENCE SYNERGY OF ARCHITECTURE & CIVIL ENGINEERING SINARG 2023, 14 - 15 September 2023, Niš, Serbiaen_US
dc.type.versionPublishedVersionen_US
Appears in Collections:Faculty of Mechanical and Civil Engineering, Kraljevo