dc.identifier.citationM. Arsić, S. Bošnjak, V. Gašić, D. Arsić, Z. Savić, State analysis of components of the damaged structure and integrity evaluation of braces at the spreader A2rs – B 5500.55+, Energija, ekonomija, ekologija, Vol.18, No.1-2, pp. 247-251, ISSN 0354-8651, 2016en_US
dc.identifier.issn0354-8651en_US
dc.identifier.urihttps://scidar.kg.ac.rs/handle/123456789/20498-
dc.description.abstractExcavation, transport and spreading of barren soil and crude ore are being performed by a number of machines during the con ti nu o us pro duction process at excavation sites, such as: bucket-wheel excavator, conveyor and spreader (so called ECS system). Failure of any machine in the technological chain leads to the failure of the whole system, and therefore it should be considered a structure with a serial connection. In this paper the results of non-destructi ve tests performed at welded joints and parent material (visual testing, penetrant testing, ultrasonic testing, radi o graphic testing, hardness testing) on the basis of which the state analysis of components of the damaged structure, integrity evaluation of braces of the cutting and discharge boom and homogeneity of welded joints of newly formed structures of the spreader A2Rs - B 5500.55 + BRs at the excavation site ’Drmno’ near Kostolac, Ser bia were performed, are presented. Taking into account the fact that the user of the spreader does not own the design and technical documentation, all tests and research presented in this paper were performed under the assumption that the lattice structures of both cutting and discharge boom were made of structural steels S355 and S235, in accordance with standard EN 10027-1.en_US
dc.description.sponsorshipThe authors acknowledge the support from the Serbian Ministry of Education, Science and Technological Development for financing Project TR 35006.en_US
dc.language.isoen_USen_US
dc.publisherSavez energetičara, Unvierzitet u Beogradu, Elektrotehnički fakultet, Univerzitet u Beogradu, Mašinski fakultet, Fakultet inženjerskih nauka Univerziteta u Kragujevcuen_US
dc.rightsinfo:eu-repo/semantics/openAccess-
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/*
dc.sourceEnergija, ekonomija, ekologija-
dc.subjectspreaderen_US
dc.subjectstate analysisen_US
dc.subjectnon-destructive testingen_US
dc.subjectlattice structureen_US
dc.subjectintegrity evaluationen_US
dc.titleState analysis of components of the damaged structure and integrity evaluation of braces at the spreader A2rs – B 5500.55+en_US
dc.typearticleen_US
dc.description.versionPublisheden_US
dc.type.versionPublishedVersionen_US
Appears in Collections:Faculty of Engineering, Kragujevac

Page views(s)

380

Downloads(s)

6

Files in This Item:
File Description SizeFormat 
M. Arsic et al._Energija-br-1-2-2016.pdf976.24 kBAdobe PDFThumbnail
View/Open


This item is licensed under a Creative Commons License Creative Commons