Please use this identifier to cite or link to this item: https://scidar.kg.ac.rs/handle/123456789/23371
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMihajlović, Stefan-
dc.contributor.authorBižić, Milan-
dc.contributor.authorDespotovic, Iva-
dc.contributor.authorBojković, Jovana-
dc.contributor.authorJanićijević, Marijana-
dc.contributor.editorMarkovic, Goran-
dc.date.accessioned2026-10-19T10:45:09Z-
dc.date.available2026-10-19T10:45:09Z-
dc.date.issued2026-
dc.identifier.isbn978-86-82434-15-3en_US
dc.identifier.urihttps://scidar.kg.ac.rs/handle/123456789/23371-
dc.description.abstractThe design of all building structures largely depends on the foundation support system, i.e., the relevant actions for structural design depend on soil structure interaction. This paper describes a methodology for measuring pressures at the contact surface between a column footing model and a soil layer limited by a rigid base using earth pressure cells. The purpose of the research is to assess the reliability of the obtained results representing contact stress distributions between the interacting components under laboratory conditions. The concept of a reduced-scale footing model is presented, along with the procedure for preparing and installing earth pressure cells in the soil, with special emphasis on their position and data acquisition method. The main factors affecting measurement accuracy are also discussed, including soil characteri stics, geometric and material properties of the tested footing model. The aim of this paper is to define an experimental procedure for a footing model and a soil layer limited by a rigid base that can serve as a basis for further experimental research and validation of numerical models. The reliability control of the measured contact stresses using earth pressure cells is based on comparison with analytical results. This experimental study examined contact pressures between a fo oting model and compacted sand using earth pressure cells. Measured pressures deviated significantly from calculated uniform values in the first test (48.3%) due to installation-induced soil disturbance, but improved to an acceptable 9.2% in the third test with proper surface preparation. The load pressure relationship remained nearly linear across all measu rements, consistent with sensor specifications.en_US
dc.description.sponsorship451-03-34/2026-03/200108en_US
dc.language.isoenen_US
dc.publisherFaculty of Mechanical and Civil Engineering in Kraljevo, University of Kragujevacen_US
dc.subjectFoundationen_US
dc.subjectGeomechanicsen_US
dc.subjectContact stressesen_US
dc.subjectColumn footingen_US
dc.subjectEarth pressure cellsen_US
dc.subjectReduced-scale footing modelen_US
dc.subjectExperimental methodologyen_US
dc.subjectSoil layer limited by a rigid baseen_US
dc.titleMethodology for measuring pressure at the contact surface between a column footing model and a soil layer limited by a rigid base using Earth pressure cellsen_US
dc.typeconferenceObjecten_US
dc.description.versionPublisheden_US
dc.identifier.doi//doi.org/10.46793/ET26.G07Men_US
dc.type.versionPublishedVersionen_US
dc.source.conferenceXII International Triennial Conference Engineering TODAYen_US
Appears in Collections:Faculty of Mechanical and Civil Engineering, Kraljevo


Files in This Item:
File SizeFormat 
ET2026-3.pdf2.76 MBAdobe PDFView/Open


Items in SCIDAR are protected by copyright, with all rights reserved, unless otherwise indicated.