Please use this identifier to cite or link to this item:
https://scidar.kg.ac.rs/handle/123456789/23465Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Popović, Novak | - |
| dc.contributor.author | Nikolić, Novak | - |
| dc.contributor.author | Živanović, Dušan | - |
| dc.contributor.author | Lukic, Nebojša | - |
| dc.date.accessioned | 2026-11-26T09:05:47Z | - |
| dc.date.available | 2026-11-26T09:05:47Z | - |
| dc.date.issued | 2026 | - |
| dc.identifier.isbn | 978-99997-941-0-7 | en_US |
| dc.identifier.uri | https://scidar.kg.ac.rs/handle/123456789/23465 | - |
| dc.description.abstract | This paper analyses the energy performance of a semi-detached residential building by comparing single-storey (ground level) and two-storey configurations. For both configurations, 3D geometric models were created in SketchUp, and energy models were subsequently developed in EnergyPlus. A total of 24 simulations were performed over the heating season, considering three thermal insulation scenarios and four building orientations (0°, 90°, 180°, and 270°). The insulation scenarios included a fully insulated building (Scenario 1), a partially insulated building without roof insulation (Scenario 2), and an uninsulated building (Scenario 3). The results were compared in terms of building configuration, thermal insulation level, and orientation. Comparison of the results across configurations showed that the difference between the two-storey and single-storey configuration is not identical for all orientations and thermal insulation scenarios. In Scenario 1, the differences range from 1.38% to 6.13%; in Scenario 2, from 0.43% to 5.03%; and in Scenario 3, from 0.86% to 2.22%. Furthermore, the two-storey configuration achieved lower heating requirements at an orientation of 90° across all three cases, whereas the single-storey configuration recorded its lowest heating requirements at 0° orientation. | en_US |
| dc.publisher | University of East Sarajevo Faculty of Mechanical Engineering East Sarajevo | en_US |
| dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | en_US |
| dc.subject | energy performance | en_US |
| dc.subject | EnergyPlus | en_US |
| dc.subject | semi-detached residential building | en_US |
| dc.subject | single-storey configuration | en_US |
| dc.subject | two-storey configuration | en_US |
| dc.title | Energy Performance of Semi-Detached Residential Buildings: A Comparison of Single-Storey and Two-Storey Conceptual Designs | en_US |
| dc.type | conferenceObject | en_US |
| dc.source.conference | 8th INTERNATIONAL SCIENTIFIC CONFERENCE ”Conference on Mechanical Engineering Technologies and Applications” COMETa2026, East Sarajevo, 2026 | en_US |
| Appears in Collections: | Faculty of Engineering, Kragujevac | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| Cometa2026_EnergyPerformanceOfSemiDetachedResidentialBuildingsAComparisonOfSingleStoreyAndTwoStoreyConceptualDesigns.pdf | 775.91 kB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License
