Please use this identifier to cite or link to this item:
https://scidar.kg.ac.rs/handle/123456789/11406
Title: | Morphological and Biomechanical Features in Abdominal Aortic Aneurysm with Long and Short Neck—Case-Control Study in 64 Abdominal Aortic Aneurysms |
Authors: | Koncar, Igor Nikolic, Dalibor Milosevic Z. Ilić N. Dragaš M. Sladojević M. Markovic M. Filipovic, Nenad Davidovic L. |
Issue Date: | 2017 |
Abstract: | © 2017 Elsevier Inc. Background Both, open and endovascular, procedures are related to higher complication rate in abdominal aortic aneurysm (AAA) with shorter neck. Previous study showed that long-neck AAA might have lower risk of rupture. Estimation of biomechanical forces in AAA improves rupture risk assessment. The aim of this study was to compare morphological features and biomechanical forces in the short- and long-neck AAA with threshold of 15 mm. Methods Digital Imaging and Communication in Medicine images of 64 aneurysms were prospectively collected and analyzed in a case-control study. Using commercially available software, Peak wall Stress (PWS) and Rupture Risk Equivalent Diameter (RRED) were determined. Difference between the maximal aneurysm diameter (MAD) and RRED was calculated and expressed as an absolute and relative (percentage of the MAD) value. In addition, volume of intraluminal thrombus (ILT) was calculated and expressed relative to AAA volume. Results Study included 64 AAA divided in group with long (36, 56.25%), and short (28, 43.75%) neck. There was no correlation between neck length and MAD, PWS, and RRED (P = 0.646, P = 0.421, and P = 0.405, respectively). Relative ILT volume was greater in the short-neck aneurysms (P = 0.033). Relative difference between RRED and MAD was −4% and −14.8% in short- and long-neck aneurysms, respectively (P = 0.029). The difference between RRED and MAD was positive in 14/28 patients (50%) with short neck and in 6/35 patients (17.14%) with long neck (P = 0.011). Conclusions Based on our biomechanical analysis, in AAA with neck longer than 15 mm rupture risk might be lower than the risk estimated by its diameter. It might be explained with lower relative volume of ILT. |
URI: | https://scidar.kg.ac.rs/handle/123456789/11406 |
Type: | article |
DOI: | 10.1016/j.avsg.2017.06.054 |
ISSN: | 0890-5096 |
SCOPUS: | 2-s2.0-85025162881 |
Appears in Collections: | Faculty of Engineering, Kragujevac Institute for Information Technologies, Kragujevac |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
PaperMissing.pdf Restricted Access | 29.86 kB | Adobe PDF | View/Open |
Items in SCIDAR are protected by copyright, with all rights reserved, unless otherwise indicated.