Please use this identifier to cite or link to this item: https://scidar.kg.ac.rs/handle/123456789/12383
Title: Determination of a CR-39 detector response to neutrons from an Am-Be source
Authors: Milenković, Biljana
Stevanović, Nenad
Nikezic, Dragoslav
Kosutic D.
Issue Date: 2014
Abstract: A comparison of experimental and calculated responses of a CR-39 detector to neutron spectra from an Am-Be source is presented. Code named Neutron_CR-39.F90 has been used to calculate the neutron dose equivalent as well as the track density. Conversion coefficient (sensitivity), between track density in track/cm2 and neutron dose equivalent in mSv, was calculated and good agreement with experimental data was found. Sensitivity increases linearly with removed layer in the range between 6μm and 24μm. © 2014 Elsevier Ltd.
URI: https://scidar.kg.ac.rs/handle/123456789/12383
Type: article
DOI: 10.1016/j.apradiso.2014.04.008
ISSN: 0969-8043
SCOPUS: 2-s2.0-84899843537
Appears in Collections:Faculty of Science, Kragujevac
Institute for Information Technologies, Kragujevac

Page views(s)

791

Downloads(s)

14

Files in This Item:
File Description SizeFormat 
PaperMissing.pdf
  Restricted Access
29.86 kBAdobe PDFThumbnail
View/Open


Items in SCIDAR are protected by copyright, with all rights reserved, unless otherwise indicated.