Please use this identifier to cite or link to this item: https://scidar.kg.ac.rs/handle/123456789/12383
Title: Determination of a CR-39 detector response to neutrons from an Am-Be source
Authors: Milenković, Biljana
Stevanović, Nenad
Nikezic, Dragoslav
Kosutic D.
Issue Date: 2014
Abstract: A comparison of experimental and calculated responses of a CR-39 detector to neutron spectra from an Am-Be source is presented. Code named Neutron_CR-39.F90 has been used to calculate the neutron dose equivalent as well as the track density. Conversion coefficient (sensitivity), between track density in track/cm2 and neutron dose equivalent in mSv, was calculated and good agreement with experimental data was found. Sensitivity increases linearly with removed layer in the range between 6μm and 24μm. © 2014 Elsevier Ltd.