Молимо вас користите овај идентификатор за цитирање или овај линк до ове ставке: https://scidar.kg.ac.rs/handle/123456789/18842
Пун извештај метаподатака
Поље DC-а ВредностЈезик
dc.contributor.authorŠimunović, Dragiša-
dc.contributor.authorKaramarkovic, Rade-
dc.contributor.authorNikolić, Miloš-
dc.contributor.authorNovčić, Đorđe-
dc.contributor.authorLazarević A.-
dc.contributor.editorSavković, Mile-
dc.date.accessioned2023-09-11T12:46:18Z-
dc.date.available2023-09-11T12:46:18Z-
dc.date.issued2021-
dc.identifier.isbn978-86-81412-09-1en_US
dc.identifier.urihttps://scidar.kg.ac.rs/handle/123456789/18842-
dc.description.abstractThe general tendency in district heating (DH) is the lowering of grid temperatures. To achieve this, heat pumps (HPs) are necessary technology that has an important role in very low (below 60 ⁰C) and ultra-low (below 45 ⁰C) DH supply temperatures. A significant variation in outdoor temperatures during the heating season in the climate of Serbia makes the implementation of HPs in the high-temperature DH systems possible. The goal of the paper is to analyze the implementation of HPs that extract heat from the shallow groundwater to satisfy a part of heat requirements in a boiler room of a DH system. This is a superheated water system with a nominal capacity of 37.728 MW and a nominal temperature regime 130/75⁰C that belongs to the PUC Toplana in Kraljevo. The city is placed at an alluvial plane rich with shallow groundwater with temperatures in the range of 12 to 18⁰C. The analysis is carried with two operating modes: (i) present, with an everyday stoppage between 9 PM and 5 AM, and (ii) continuous operation with limited overnight heating. Not to endanger the inflow, the maximal extraction of the heat from groundwater of 755 kW was assumed. The present operating mode would have seasonal COP 3.87 and negative economic indicators, whereas the continuous operation would lead to a sustainable project with a financial rate of return of 10.5%, benefit-cost ratio of 1.192, and the reduction of CO2 emissions of 201 t/year. The seasonal COP of the HPs would be 4.29.en_US
dc.language.isoenen_US
dc.publisherFACULTY OF MECHANICAL AND CIVIL ENGINEERING KRALJEVO UNIVERSITY OF KRAGUJEVACen_US
dc.rightsinfo:eu-repo/semantics/openAccess-
dc.sourceHEAVY MACHINERY HM 2021en_US
dc.subjectdistrict heatingen_US
dc.subjectwater source heat pumpsen_US
dc.subjectshallow groundwateren_US
dc.subjectcost-benefit analysisen_US
dc.titleThe usage of shallow groundwater heat by heat pumps in a high- temperature district heating systemen_US
dc.typeconferenceObjecten_US
dc.description.versionPublisheden_US
dc.type.versionPublishedVersionen_US
Налази се у колекцијама:Faculty of Mechanical and Civil Engineering, Kraljevo

Број прегледа

834

Број преузимања

19

Датотеке у овој ставци:
Датотека Опис ВеличинаФормат 
HM_2021_Rad 2.pdf1.66 MBAdobe PDFСличица
Погледајте


Ставке на SCIDAR-у су заштићене ауторским правима, са свим правима задржаним, осим ако није другачије назначено.