Please use this identifier to cite or link to this item: https://scidar.kg.ac.rs/handle/123456789/22050
Full metadata record
DC FieldValueLanguage
dc.contributor.authorNikolić, Novak-
dc.contributor.authorJurišević, Nebojša-
dc.contributor.authorGordić, Dušan-
dc.contributor.authorLukic, Nebojsa-
dc.contributor.authorJovanović, Davor-
dc.contributor.authorDagović, Vujadin-
dc.contributor.authorNešović, Aleksandar-
dc.date.accessioned2025-01-30T08:15:59Z-
dc.date.available2025-01-30T08:15:59Z-
dc.date.issued2025-
dc.identifier.issn0378-7788en_US
dc.identifier.urihttps://scidar.kg.ac.rs/handle/123456789/22050-
dc.description.abstractThe main objective of this research is to develop the representative of realistic occupancy patterns for kindergartens in Serbia that would be used as input for dynamic building energy simulation tools. The current study is unique in a sense that developed patterns, extracted from the actual occupancy data for existing kindergartens, include not only daily but also annual variations in occupancy presence. Variable, fixed (average and maximum) and actual occupancy patterns were generated and then introduced into a building energy models to quantify and compare their impact on the energy behavior of the case study existing kindergarten. The building energy consumption obtained for the actual patterns was considered as the reference case. Simulation results revealed that the people occupancy can have a major impact on the energy performance of educational buildings. There are significant differences between variable and fixed occupancy patterns. The average seasonal deviations for heating and cooling consumption compared to the reference case are: 4.83% (variable), 6.92% (fixed average), 34.35% (fixed maximum) and 4.18% (variable), 12.18% (fixed average), 36.89% (fixed maximum), respectively. Fan electricity use discrepancies for heating and cooling season amounts: 12.37% (variable), 19.39% (fixed average), 94.54% (fixed maximum) and 8.75% (variable), 28.95% (fixed average), 101.83% (fixed maximum), respectively. These findings confirmed the reliability of the proposed variable patterns and proved that conventional patterns, given in standards or rulebooks, which are fixed throughout the year, can significantly reduce the accuracy of energy performance prediction of a buildings with dynamic variations in people occupancy, such as educational buildings.en_US
dc.language.isoenen_US
dc.relation.ispartofEnergy and Buildingsen_US
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 United States*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/*
dc.subjectoccupancyen_US
dc.subjectpatternen_US
dc.subjecteducational buildingen_US
dc.subjectenergy consumptionen_US
dc.subjectsimulationen_US
dc.titleImpact of occupancy patterns on energy performance of kindergarten buildings–A case study of Serbiaen_US
dc.typearticleen_US
dc.identifier.doi10.1016/j.enbuild.2024.115266en_US
Appears in Collections:Faculty of Engineering, Kragujevac
Institute for Information Technologies, Kragujevac

Page views(s)

287

Downloads(s)

11

Files in This Item:
File Description SizeFormat 
NN-EB-2025 scidar.pdf
  Restricted Access
3.28 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons