Молимо вас користите овај идентификатор за цитирање или овај линк до ове ставке: https://scidar.kg.ac.rs/handle/123456789/22051
Назив: MECHANICAL VAPOR COMPRESSION DESALINATION PLANT – EFFICIENCY INCREASING POSSIBILITIES OF PROCESS USING DROPWISE CONDENSATION
Аутори: Lukic, Nebojsa
Leipertz, Alfred
Fröba, Andreas Paul
Diezel L.
Датум издавања: 2005
Сажетак: Using ion-implanted metallic surfaces to provoke a dropwise condensation improves a convective heat transfer coefficient significantly. Thermal desalination process, especially mechanical vapor compression (MVC) could be more effective by ion-implantation technology. This paper points on a possible heat transfer area reduction using defined approach. In defined MVC plant simulation model (mathematical model and realized software), a replacing filmwise by dropwise condensation can improve both main convective heat transfer process (condensation and evaporation) by arising a condensation heat transfer coefficient and also a heat flux value (respectively). For assumed improvement factor of dropwise condensation, comparing with filmwise condensation by the same MVC plant capacity, the reduction of main heat exchanger area is within 40% and 45%.
URI: https://scidar.kg.ac.rs/handle/123456789/22051
Тип: conferenceObject
Налази се у колекцијама:Faculty of Engineering, Kragujevac

Број прегледа

204

Број преузимања

3

Датотеке у овој ставци:
Датотека Опис ВеличинаФормат 
Simterm 2005.pdf501.06 kBAdobe PDFСличица
Погледајте