Please use this identifier to cite or link to this item:
https://scidar.kg.ac.rs/handle/123456789/9916
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.rights.license | restrictedAccess | - |
dc.contributor.author | Nikolic, Milica | - |
dc.contributor.author | Filipovic, Nenad | - |
dc.date.accessioned | 2021-04-20T14:23:48Z | - |
dc.date.available | 2021-04-20T14:23:48Z | - |
dc.date.issued | 2011 | - |
dc.identifier.uri | https://scidar.kg.ac.rs/handle/123456789/9916 | - |
dc.description.abstract | A three-dimensional finite element model for endocardial radiofrequency ablation is presented. During ablation process it is very important to calculate generated temperature field. This field is formed around electrode, in the contact point with the heart muscle. We investigated generated temperature field and temperature distribution across the heart for three cases: 1) when blood flow through the coronary artery is regular, 2) when blood flow through the coronary artery is equal zero, and 3) when there is no blood in the coronary artery (the air was modeled). Beside that there are many parameters which have to be determined: dimensions of lesions (wounds, by heat affected and destroyed area), effect of blood flow on forming temperature field (either through coronary artery or heart), use of saline [1] and its layer thickness, used voltage on electrode, contact width between electrode and heart, etc. Effects of parameters, such as blood flow rate and applied power (voltage on the electrode) are investigated. It is shown that the blood flow in the coronary artery does not have significant influence on the temperature distribution. Also, temperature of range 50°-100 C for applied constant voltage of 15V is a good choice. © 2011 IEEE. | - |
dc.rights | info:eu-repo/semantics/restrictedAccess | - |
dc.rights | info:eu-repo/semantics/restrictedAccess | - |
dc.source | 10th International Workshop on Biomedical Engineering, BioEng 2011 | - |
dc.title | Modeling ablation on the endocardium and temperature distribution during RF ablation | - |
dc.type | conferenceObject | - |
dc.identifier.doi | 10.1109/IWBE.2011.6079030 | - |
dc.identifier.scopus | 2-s2.0-83255165686 | - |
Appears in Collections: | Faculty of Engineering, Kragujevac Institute for Information Technologies, Kragujevac |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
PaperMissing.pdf Restricted Access | 29.86 kB | Adobe PDF | ![]() View/Open |
Items in SCIDAR are protected by copyright, with all rights reserved, unless otherwise indicated.