Title: Design of noise protection of industrial plants - case study of a plywood factory
Authors: Radičević, Branko
Petrović, Zoran
Todosijević, Slobodan
Petrović, Zvonko
Issue Date: 2012
Abstract: The paper presents activities of reduction of noise emitted by plywood factory facilities. Dominant noise sources in the factory, which caused noise levels above limits, were identified. Based on calculation of acoustic fields performed by original software package, a noise map of the endangered area was created, and a noise protection system was designed. The noise protection system consists of two sound barriers, insulation of noise sources and changes of organization of the technology process. Application of the noise protection system led to reduction of specific noise levels for 14 dB. Noise levels at a control site in residential areas during day do not overcome limits anymore.